In-shop and field service technicians are highly trained and certified in all critical areas of rotating electrical equipment testing. As an Authorized Service & Repair Center for many of the world’s most popular brands, we repair to the industry’s highest standards, with the goal of achieving “as good as new” condition.

All of our locations:

  • Are outfitted with advanced technologies to ensure precision test environments and results
  • Enable us to diagnose and document outcomes throughout a range of individual processes

Our Texas and Louisiana locations:

  • Offer state-of-the-art dyno testing facilities
  • Perform factory equivalent full load testing of generators & motors, both A/C & D/C
  • Are equipped with powerful 2,500 horsepower regeneration drive systems
  • Enable you to comply with ABS, DNV, UL & Lloyds inspections — & acquire industry required re-certifications through our repair & testing capabilities

Critical Motor & Generator Testing Capabilities

Ward Leonard conducts a wide range of tests to ensure performance standards are met, including capturing diagnostics to measure against benchmarks, and uncover usage and electromechanical trends.

  • Air gap
  • Bearing
  • Capacitor
  • Core loss
  • AC & DC H-Ppot
  • Insulation resistance
  • Mechanical fit
  • Megger®
  • Motor circuit evaluation (MCE)
  • NDE shaft
  • Thermography
  • Vibration
  • Voltage drop
  • Partial discharge
  • Polarization index
  • Power circuits
  • Power quality
  • Rectifiers
  • Resistance imbalance
  • Rotor influence
  • Rotor
  • Static
  • Surge
  • Voltage regulator

Load Testing Ensures Performance & Uptime

Motors and generators are costly investments, and Ward Leonard utilizes state-of-the-art load testing technologies to identify any issues before they happen and ensure your equipment is optimized for full productivity. Our capabilities include:

  • Critical vibration, stator RTD, bearing BTD, amperage & voltage testing
  • Efficiency profiles at multiple power & speed points
  • Horizontal & vertical load testing
  • Full load testing of generators up to 20 megawatts at 480—13,800 VAC
  • Full load testing of A/C motors up to 2,500 HP, 240—13,800 VAC
  • Full load testing of D/C motors up to 3,000 HP
  • 2,500 HP regeneration drive system at each facility
  • Vertical derricks to load test pump, thruster, top drive & all other types of vertical motors

Real-Time Web Viewing
No time to be on-site during testing? No problem: we have installed a unique four-camera live-feed system that enables you to view testing “anytime / anywhere” via a personalized web page.

 

Click here to View in Real Time